Difference between revisions of "Lip(Sys)2/Near-infrared Spectroscopy"

From DAAP
Jump to navigation Jump to search
Line 8: Line 8:
 
| Keywords = FT-NIR, NearInfrared, SPIR, ProcheInfrarouge
 
| Keywords = FT-NIR, NearInfrared, SPIR, ProcheInfrarouge
 
| Picture = http://daap.eu/w/images/d/d0/Nirflex_N500_low_res.jpg
 
| Picture = http://daap.eu/w/images/d/d0/Nirflex_N500_low_res.jpg
| Latitude =  
+
| Latitude = 48.7618867
| Longitude =
+
| Longitude = 2.273395
 
}}
 
}}
  
 
== Büchi NirFlex N500 ==
 
== Büchi NirFlex N500 ==
 
[[File:Nirflex N500 sample holders.jpg]]
 
  
 
The Büchi Nirflex N500 is a Fourier Transform Near-Infrared spectrometer suited for the analysis of solids by diffuse reflectance.  
 
The Büchi Nirflex N500 is a Fourier Transform Near-Infrared spectrometer suited for the analysis of solids by diffuse reflectance.  
Line 25: Line 23:
 
- XL vials (e.g. a 20 ml glass scintillation vial or larger),  plastic bags (single sample)
 
- XL vials (e.g. a 20 ml glass scintillation vial or larger),  plastic bags (single sample)
 
The illumination spot diameter is 9 mm for Petri plates and XL Vials sample holders and 8 mm for 2mL vials and Tablets holders.
 
The illumination spot diameter is 9 mm for Petri plates and XL Vials sample holders and 8 mm for 2mL vials and Tablets holders.
 +
 +
[[File:Nirflex N500 sample holders.jpg]]
 +
 +
Le Büchi NirFlex N500 est un spectromètre Proche-Infrarouge à transformée de Fourier utilisable pour l’analyse des solides par réflectance diffuse.
 +
La gamme spectrale est de 800 à 2500 nm (12 500~4000 cm-1) avec une résolution de 8 cm-1. La vitesse de balayage est de 2 spectres/seconde.
 +
Les données spectrales peuvent être traitées par le logiciel de chimiométrie propriétaire Nircal® (ACP, SIMCA, PLS) ou exportées au format JCAMP-DX pour un traitement de données plus poussé.
 +
 +
Quatre adaptateurs sont disponibles pour :
 +
- Les flacons de 2 mL type HPLC (6 positions)
 +
- Les boites de Petri pour les solides en vrac (1 seul échantillon)
 +
- Les comprimés et les gélules par analyse directe (10 positions)
 +
- Les flacons XL de grande taille (type compteur à scintillation) ou en sac plastique (1 seul échantillon)
 +
Le diamètre de la zone illuminée est de 9 mm pour le dispositif Petri ou XL et de 8 mm pour les flacons de 2 mL ou comprimés.

Revision as of 10:50, 27 January 2016

Under construction
Device
Nirflex_N500_low_res.jpg

Pilot process
Keywords
Organisation
Latitude
48.7618867
Longitude
2.273395

Büchi NirFlex N500

The Büchi Nirflex N500 is a Fourier Transform Near-Infrared spectrometer suited for the analysis of solids by diffuse reflectance. The spectral range is from 800 to 2500 nm (12 500 ~4000 cm-1) with an 8cm-1 resolution. The scan speed is 2 scans/second. Spectral data can be processed by the proprietary Nircal® chemometric software (PCA, SIMCA, PLS algorithms) or exported to the JCAMP-DX format for further data processing. Four adapters are available to accommodate: - 2mL vials such as HPLC autosamplers vials (6 positions) - Petri plates for bulk solids (single sample) - Tablets for direct analysis of tablets (round or oval shaped) and capsules (10 pos.) - XL vials (e.g. a 20 ml glass scintillation vial or larger), plastic bags (single sample) The illumination spot diameter is 9 mm for Petri plates and XL Vials sample holders and 8 mm for 2mL vials and Tablets holders.

Nirflex N500 sample holders.jpg

Le Büchi NirFlex N500 est un spectromètre Proche-Infrarouge à transformée de Fourier utilisable pour l’analyse des solides par réflectance diffuse. La gamme spectrale est de 800 à 2500 nm (12 500~4000 cm-1) avec une résolution de 8 cm-1. La vitesse de balayage est de 2 spectres/seconde. Les données spectrales peuvent être traitées par le logiciel de chimiométrie propriétaire Nircal® (ACP, SIMCA, PLS) ou exportées au format JCAMP-DX pour un traitement de données plus poussé.

Quatre adaptateurs sont disponibles pour : - Les flacons de 2 mL type HPLC (6 positions) - Les boites de Petri pour les solides en vrac (1 seul échantillon) - Les comprimés et les gélules par analyse directe (10 positions) - Les flacons XL de grande taille (type compteur à scintillation) ou en sac plastique (1 seul échantillon) Le diamètre de la zone illuminée est de 9 mm pour le dispositif Petri ou XL et de 8 mm pour les flacons de 2 mL ou comprimés.