Difference between revisions of "Lip(Sys)2/Near-infrared Spectroscopy"

From DAAP
Jump to navigation Jump to search
Line 2: Line 2:
  
 
{{#invoke:Device|infobox
 
{{#invoke:Device|infobox
| Title =
+
| Title = Büchi NirFlex N500
 
| Organisation =  
 
| Organisation =  
| Pilote process =  
+
| Pilote process = Pierre Chaminade
 
| Website =  
 
| Website =  
| Keywords =
+
| Keywords = FT-NIR, NearInfrared, SPIR, ProcheInfrarouge
 
| Picture =  
 
| Picture =  
 
| Latitude =  
 
| Latitude =  
 
| Longitude =
 
| Longitude =
 
}}
 
}}
 +
 +
== Büchi NirFlex N500 ==
 +
 +
The Büchi Nirflex N500 is a Fourier Transform Near-Infrared spectrometer suited for the analysis of solids by diffuse reflectance.
 +
The spectral range is from 800 to 2500 nm (12 500 ~4000 cm-1) with an 8cm-1 resolution. The scan speed is 2 scans/second.
 +
Spectral data can be processed by the proprietary Nircal® chemometric software (PCA, SIMCA, PLS algorithms) or exported to the JCAMP-DX format for further data processing.
 +
Four adapters are available to accommodate:
 +
- 2mL vials such as HPLC autosamplers vials (6 positions)
 +
- Petri plates for bulk solids (single sample)
 +
- Tablets for direct analysis of tablets (round or oval shaped) and capsules (10 pos.)
 +
- XL vials (e.g. a 20 ml glass scintillation vial or larger),  plastic bags (single sample)
 +
The illumination spot diameter is 9 mm for Petri plates and XL Vials sample holders and 8 mm for 2mL vials and Tablets holders.

Revision as of 10:08, 27 January 2016

Under construction
Device
Nirflex_N500_low_res.jpg

Pilot process
Keywords
Organisation
Latitude
48.7623
Longitude
2.27359

Büchi NirFlex N500

The Büchi Nirflex N500 is a Fourier Transform Near-Infrared spectrometer suited for the analysis of solids by diffuse reflectance. The spectral range is from 800 to 2500 nm (12 500 ~4000 cm-1) with an 8cm-1 resolution. The scan speed is 2 scans/second. Spectral data can be processed by the proprietary Nircal® chemometric software (PCA, SIMCA, PLS algorithms) or exported to the JCAMP-DX format for further data processing. Four adapters are available to accommodate: - 2mL vials such as HPLC autosamplers vials (6 positions) - Petri plates for bulk solids (single sample) - Tablets for direct analysis of tablets (round or oval shaped) and capsules (10 pos.) - XL vials (e.g. a 20 ml glass scintillation vial or larger), plastic bags (single sample) The illumination spot diameter is 9 mm for Petri plates and XL Vials sample holders and 8 mm for 2mL vials and Tablets holders.